CXCAN Connector
The CXCAN connector is a female DB9 connector, with standard CANBUS pinout, built inside a conductive shell.
The shell contains a printed circuit boardd, and has a double fairlead, one for the incoming cable, and one for the outgoing cable. Each cable has a clamp for the conductive shield.
On the PCB a common mode filter is available on the CAN_H, and CAN_L signals to increase protection against noise, and power surges. A 6 points terminal is also available for CAN_L, CAN_H, and CAN_GND input, and for CAN_L, CAN_H, and CAN_GND output.
A jumper is available for CANBUS line termination.
Technical specifications
Dimensions (H x W x D) | 52 x 40 x 18 mm |
Mounting | Conductive shell |
CanBus Connector | DB9 |
Filter | 2x51uH common mode inductance |
Protection | Thyrector berween CAN_H, CAN_L, and CAN_GND |
Terminazion | Jumper |
Marking | CE |
Operatign Temperature | 0 - 55 °C |
Storage Temperature | -20 - 85 °C |
Warehousing Humidity | Max 85% non-condensing |